پرینت 

INTEGRA 64 Plus

EN50131 GRADE 3 COMPLIANT ALARM CONTROL PANEL MAIN BOARD, WITH 16 
UP TO 64 ZONES AND OUTPUTS 
Due to their full compliance with the requirements ofEN50131 Grade 3, the INTEGRA Plus control units are perfectly fitfor implementation of advanced security systems at locations withparticularly high risk of burglary, such as banks, jewellery stores orpublic utility facilities. The control units are characterised by extendedfunctionality, due to which they can be used for implementation ofaccess control systems or even intelligent building solutions. 
full compliance with EN50131 series of standards for Grade
3 equipment
built–in advanced 2 A+1.5 A power supply with
extended autodiagnostics
up to 64zones with programmable EOL value and support for
3 EOL configuration (only mainboard zones)
USB port for programming via PC
up to 32 partitions, 8 tenants
up to 64 fully programmable outputs
dedicated buses for communication with keypads and
expansion modules
system operation via LCD keypads, partition keypads, remote control keyfobs or proximity cards
remote system operation with PC, smartphone or voice–guided telephone menu
64 independent timers for automatic control
access control and home automation features 
non–volatile event log with 5631 entries, with on–line printing support
support for 192+8+1 user codes
firmware upgrades via PC
option of not reporting server SATEL failure to the control panel (INTEGRA Firmware 1.16 or newer) 
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only. www.satel.eu 
INTRUDER ALARMS 
Alarm control panels / INTEGRA / PCB 
INTRUDER ALARMS 
Alarm control panels / INTEGRA / PCB 
TECHNICAL DATA 
Installer-defined text messaged 64 
Extender circuits up to 64 
Environmental class according to EN50130-5 II 
Voice messages 16 
Communication buses 1+2 
Maximum number of programmable inputs 64 
Maximum number of programmable outputs 64 
Maximum humidity 93±3% 
Maximum current consumption from the battery 200 mA 
Maximum current consumption from the 230V network 400 mA 
Maximum battery charging current 1500 mA 
Manipulators up to 8 
Weight 320 g 
Battery cut-off voltage (±10%) 10,5 V 
Power supply output voltage 10,5…14 V DC 
Supply voltage (±15%) 20 V AC, 50-60 Hz 
Battery failure voltage threshold (±10%) 11 V 
Telephone numbers for notification (voice/PAGER + SMS) 16+16 
Carrying capacity of the +EX1 and +EX2 outputs (±10%) 3000 mA 
Low current programmable outputs rating 50 mA 
High current programmable outputs rating 3000 mA 
Carrying capacity of the +KPD output (±10%) 3000 mA 
Event log 5631 
Objects 8 
Current consumption from the 230V network in standby 135 mA 
Current consumption from battery - standby 130 mA 
Security grade according to EN 50131 Grade 3 
Partitions 32 
Timers 64 
Users + Administrators 192 + 8 
Programmable wired inputs 16 
Power supply current efficiency (supplying devices + charging batteries) 2000 + 1500 mA 
Programmable wired outputs 16 
Supplying outputs 3 
Board dimensions 264 x 134 mm 
Operating temperature range -10…+55 °C 
Recommended transformer type 75 VA 
he actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only. www.satel.eu

 