INTEGRA 64 Plus
EN50131 GRADE 3 COMPLIANT ALARM CONTROL PANEL MAIN BOARD, WITH 16
UP TO 64 ZONES AND OUTPUTS
Due to their full compliance with the requirements ofEN50131 Grade 3, the INTEGRA Plus control units are perfectly fitfor implementation of advanced security systems at locations withparticularly high risk of burglary, such as banks, jewellery stores orpublic utility facilities. The control units are characterised by extendedfunctionality, due to which they can be used for implementation ofaccess control systems or even intelligent building solutions.
full compliance with EN50131 series of standards for Grade
3 equipment
built–in advanced 2 A+1.5 A power supply with
extended autodiagnostics
up to 64zones with programmable EOL value and support for
3 EOL configuration (only mainboard zones)
USB port for programming via PC
up to 32 partitions, 8 tenants
up to 64 fully programmable outputs
dedicated buses for communication with keypads and
expansion modules
system operation via LCD keypads, partition keypads, remote control keyfobs or proximity cards
remote system operation with PC, smartphone or voice–guided telephone menu
64 independent timers for automatic control
access control and home automation features
non–volatile event log with 5631 entries, with on–line printing support
support for 192+8+1 user codes
firmware upgrades via PC
option of not reporting server SATEL failure to the control panel (INTEGRA Firmware 1.16 or newer)
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only. www.satel.eu
INTRUDER ALARMS
Alarm control panels / INTEGRA / PCB
INTRUDER ALARMS
Alarm control panels / INTEGRA / PCB
TECHNICAL DATA
Installer-defined text messaged 64
Extender circuits up to 64
Environmental class according to EN50130-5 II
Voice messages 16
Communication buses 1+2
Maximum number of programmable inputs 64
Maximum number of programmable outputs 64
Maximum humidity 93±3%
Maximum current consumption from the battery 200 mA
Maximum current consumption from the 230V network 400 mA
Maximum battery charging current 1500 mA
Manipulators up to 8
Weight 320 g
Battery cut-off voltage (±10%) 10,5 V
Power supply output voltage 10,5…14 V DC
Supply voltage (±15%) 20 V AC, 50-60 Hz
Battery failure voltage threshold (±10%) 11 V
Telephone numbers for notification (voice/PAGER + SMS) 16+16
Carrying capacity of the +EX1 and +EX2 outputs (±10%) 3000 mA
Low current programmable outputs rating 50 mA
High current programmable outputs rating 3000 mA
Carrying capacity of the +KPD output (±10%) 3000 mA
Event log 5631
Objects 8
Current consumption from the 230V network in standby 135 mA
Current consumption from battery - standby 130 mA
Security grade according to EN 50131 Grade 3
Partitions 32
Timers 64
Users + Administrators 192 + 8
Programmable wired inputs 16
Power supply current efficiency (supplying devices + charging batteries) 2000 + 1500 mA
Programmable wired outputs 16
Supplying outputs 3
Board dimensions 264 x 134 mm
Operating temperature range -10…+55 °C
Recommended transformer type 75 VA