پرینت 

ACCO-KPWG-PS

Standalone door controller supporting Wiegand

 

The ACCO-KPWG-PS module is designed for control of a single door within the ACCO access control system. The module can also be used as a standalone device. User authorization is based on code or passive transponder (proximity card, tag, etc.). ACCO-KPWG-PS is also compatible with terminals supporting Wiegand and EM Marin protocols, as well as with iButton (Dallas chip) readers.

The device is characterized by a wide range of settings, including the user rights and time schedules for each user, including special holiday schedules. Additionally, event log with more than 24,000 events is available. Non-volatile flash memory ensures security of the module settings in case of power failure. ACCO-KPWG-PS is provided with a relay output for operating electromagnetic lock or another door activating device. Owing to additional inputs and outputs, the module can work in conjunction with the alarm system. The ACCO-KPWG-PS module is an enhanced version of the ACCO-KPWG door controller, provided with a built-in backup power supply.

Configuration and some functions of ACCO-KPWG-PS might be different due to the system, which the controller is part of. Within the ACCO system the module is programmed by means of an LCD keypad or PC computer with ACCO-SOFT-LT software installed. The PC can be connected via RS-232 port or via RS-485 bus using ACCO-USB converter. In the ACCO NET system, the controller configuration is performed using the ACCO Soft software.

support for single door with entry and exit authorization

support for terminals using the following transmission protocols:

EM Marin (SATEL terminals)

Wiegand 26

Wiegand 32, 34, 36, 40, 42, 56 (controllers firmware version 3.02, release date 2017-11-03 or newer - applies to ACCO NET system)

Dallas

standalone or ACCO/ACCO NET system operation mode

1,024 users

user rights definition

access authorization with proximity card and/or code

biometric authorization

256 schedules

holiday schedules

non-volatile 24,576 event log

work time registration event tagging

anti-passback

programming means:

permanently or temporarily connected LCD keypad

PC connected via RS-232 port

PC connected via ACCO-USB interface to RS-485 bus

non volatile settings memory

FLASH based firmware update

scheduled door locking and unlocking

programmable limits on number of accesses

switching mode backup power supply 12 V DC 1.2 A

Attention!

ACCO-KPWG-PS controller in version:

2.03 works with ACCO-SOFT-LT software only in version 1.03

3.00 works with ACCO-SOFT-LT software in version 1.04 or 1.05

3.01 works with ACCO-SOFT-LT software in version 1.05 or 1.07.004

To cooperate with the ACCO-NT access control panel, the controller must be in version 3.00 or newer.

ACCO-KPWG-PS controller in version:

3.02 works with ACCO-NT access control panel in version 1.12.xxx

3.03 works with ACCO-NT access control panel in version 1.13.xxx

3.04 works with ACCO-NT access control panel in version 1.14.023

3.05 works with ACCO-NT access control panel in version 1.14.026 

 

دزدگیر ستل ( ساتل ) قیمت : تماس